KINCO
38
1.Click”scp configurator”--->”scanning ”or” add device”--->”next”, pay attention to the default
controller IP: 192.168.1.1. And set IP 192.168.1.1 in the software (PC and controller must be set
up in the same segment), ping IP address is OK, that configuration is successful. Save and close
“scp configurator”--->”refresh” to see logical devices created in configured logical devices”,
double-click to enter. All configurations will be successful.
2.Open ”indralogic”--->”online/communication parameter”--->”new” and select ”TCP/IP” to
modify “value”, set IP address the same as controller: 192.168.1.1
3. “Resource”--->“Global variables”--->declare variable in “HMI”