Mitigator: detecting rogue access points
A31003-W1010-A100-1-7619, July 2005
130 HiPath Wireless Controller, Access Points and Convergence Software V3.0: User Guide
HWC_Mitigator.fm
Enabling the Analysis and RFDC Engines
11.2 Enabling the Analysis and RFDC Engines
Enable and configure the Mitigator Analysis Engine
1. In the HiPath Wireless Controller Configuration screen, click on the Mitigator option. The
Mitigator Configuration screen appears.
2. To enable the Mitigator Analysis Engine, click the checkbox on.
Define the Mitigator RF Data Collector Engines
3. To enable the Mitigator Data Collection Engine on this HiPath Wireless Controller click
the checkbox on.
4. Identify the remote RF Data Collector Engines that the Analysis Engine will poll for data: In
the Collection Engine IPs entry field, key in the IP address of the HiPath Wireless
Controller on which the remote RFDC resides. (For this HiPath Wireless Controller, the
local IP address is displayed by default.)
5. For each data collection engine, enter:
In the Poll interval field (the interval that the Analysis Engine polls the RF Data
Collector for data), key in the time in seconds. Default is 30 seconds.
In the Poll retry count field, key in the number of times the Analysis Engine will
attempt to poll the RF Data Collector for data before it stops sending requests. Default
is 2 attempts.
6. Click on the Add button. The IP address of the Data Collection Engine, with its Poll Interval
and Poll Retry parameters, appears in the list.