Logs and Events
A31003-W1010-A100-1-7619, July 2005
230 HiPath Wireless Controller, Access Points and Convergence Software V3.0: User Guide
HWC_AppendixG.fm
Major
G.3.7 LANGLEY
EVENT_SERVER
Severity Major
Log Message Cannot reset audit file pointer to beginning of the audit file - Error no:
%d. The message and subsequent messages will be dropped.
Description Audit file circular buffer problem.
Action Indicates that the audit file may be corrupted, or the logging partition is
full or corrupted. Try deleting the audit file and restarting the event
server.
Table G-86
EVENT_SERVER
Severity Major
Log Message Cannot set audit file pointer to specific position in the log - Error no: %d.
The message and subsequent messages will be lost.
Description Audit file circular buffer problem.
Action Indicates that the audit file could be corrupted or that the logging
partition is full or corrupted. Try deleting the audit file and restarting the
event server.
Table G-87
LANGLEY
Severity Major
Log Message Langley has experienced an error which has prevented it from properly
processing a request. Langley will continue running, however this error
may be an indicator of a larger system problem. Error Details: %s
Description Internal messaging problem.
Action No action required. However, monitoring for re-occurrence is
recommended. Other event logs may indicate that a component has
failed and been re-started.
Table G-88