Logs and Events
A31003-W1010-A100-1-7619, July 2005
214 HiPath Wireless Controller, Access Points and Convergence Software V3.0: User Guide
HWC_AppendixG.fm
Critical
G.2.8 RF_DATA_COLLECTOR
RADIUS_CLIENT
Severity Critical
Log Message Failed to send process status success to Startup Manager. Start-up
Manager will reboot the RADIUS client.
Description Interprocess communication failure.
Action No action required.
Table G-40
RADIUS_CLIENT
Severity Critical
Log Message No radius server available for VNS: %s.
Description None of the RADIUS servers configured for a VNS are reachable by the
RADIUS client.
Action Indicates that network connectivity needs to be checked. The system is
operating correctly, but the external connections have been lost. No
RADIUS servers can be contacted for client authentication.
Table G-41
RF_DATA_COLLECTOR
Severity Critical
Log Message An error has occurred in the RF Data Collector which will cause this
component to shutdown (and be restarted by the system). Details:%s.
Description Indicates an internal service failure.
Action Monitor the system for re-occurrences. If it appears under similar
operating circumstances, there may be data corruption in the network.
If other parts of the controller begin to behave erratically, this may
indicate a hardware failure. Contact service as the controller may need
servicing.