Siemens C10 Betriebsanweisung Seite 225

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 250
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 224
HWC_AppendixG.fm
A31003-W1010-A100-1-7619, July 2005
HiPath Wireless Controller, Access Points and Convergence Software V3.0: User Guide
223
Logs and Events
Major
G.3 Major
The following subsections contain tables describing all Major log messages. The sections are
listed alphabetically by Component Name.
G.3.1 ACCESSPOINT
ACCESSPOINT
Severity Major
Log Message Communication with Access Controller lost. AP - AC poll timeout.
Description AccessPoint poll timed out.
Action Check the IP connection between Access controller and Access Point.
If the Heartbeat between AC and AP timed out, check the configuration
of AP poll and timeout periods.
Table G-64
ACCESSPOINT
Severity Major
Log Message AccessPoint Problem Report captured. Ap-report-5.txt (size 37222
bytes).
Description AccessPoint Problem Report captured.
Action AP detected a problem and captured relevant data to a file. Upload ap-
report file to Access controller and send it to field support. The file will
be analyzed by Siemens to resolve and correct the problem.
Table G-65
ACCESSPOINT
Severity Major
Log Message AccessPoint software upgrade done. File size is 1500222.
Description AccessPoint software upgrade done.
Action None. AP software upgrade has been successfully completed.
Table G-66
Seitenansicht 224
1 2 ... 220 221 222 223 224 225 226 227 228 229 230 ... 249 250

Kommentare zu diesen Handbüchern

Keine Kommentare