HWC_AppendixG.fm
A31003-W1010-A100-1-7619, July 2005
HiPath Wireless Controller, Access Points and Convergence Software V3.0: User Guide
217
Logs and Events
Critical
G.2.11 STARTUP_MANAGER
SECURITY_MANAGER
Severity Critical
Log Message Error binding to listener socket. Will not be able to communicate with
Apache server.
Description Inter-component communication failure.
Action Verify that the web server is still running. If it is, re-start the security
manager process to clear the problem.
Table G-49
SECURITY_MANAGER
Severity Critical
Log Message Listen call failed. Will not be able to communicate with Apache Server.
Description Inter-component communication failure.
Action Verify that the web server is still running. If it is, re-start the security
manager process to clear the problem.
Table G-50
SECURITY_MANAGER
Severity Critical
Log Message Socket call failed. Will not be able to communicate with specific
component.
Description Inter-component communication failure.
Action Indicates that a service the Security Manager depends on has failed.
There may be another event from the Start-up Manager indicating that
a service has been restarted.
Table G-51
STARTUP_MANAGER
Severity Critical
Table G-52