Setting-up
4.2 Limit stops
Manual Machine Plus Turning
28 Programming and Operating Manual, 06/2009, 6FC5398-6CP10-1BA0
Operating sequences
You can use the following methods to enter a limit stop position:
● Direct position entry:
– Select the input field of the relevant limit stop with the <Cursor keys>.
– Now use the <Numeric keys> to enter the absolute position you require.
– Press the <INPUT> key to accept the value.
● Accepting the current actual position:
– Select the input field of the relevant limit stop with the <Cursor keys>.
– Traverse to the required position using the axis direction switch (e.g. <-Z> or <+X/-
X/+Z>).
– Press the "Set limit stop" softkey.
The current actual position of the relevant axis is transferred to the input field.
Activating/disabling limit stops
The limit stops are activated/de-activated individually using the <SELECT> key.
You can select between ON and OFF.
=
6HW
OLPLWVWRS