Parameter Function Range [factory setting]
MICROMASTER MICRO/MIDIMASTER Vector
P087 • Motor PTC enable - 0 - 1 [0]
P088 Automatic calibration - 0 - 1 [1]
P089 • Stator resistance (Ω) 0.01 - 100.00 [²²²] 0.01 - 199.00 [²²²]
P091 • Serial link slave address 0 - 30 [0] 0 - 30 [0]
P092 • Serial link baud rate 3 - 7 [6] 3 - 7 [6]
P093 • Serial line time-out (seconds) 0 - 240 [0] 0 - 240 [0]
P094 • Serial link nominal system setpoint (Hz) 0.00 - 400.00 [50.00] 0.00 - 650.00 [50.00]
P095 • USS compatibility 0 - 2 [0] 0 - 2 [0]
P099 • Option module type 0 - 2 [0] 0 - 2 [0]
P101 • Operation for Europe or North America 0 - 1 [0] 0 - 1 [0]
P111 Inverter power rating (kW/hp) 0.0 - 75.0 [²²²] 0.0 - 75.0 [²²²]
P112 • Inverter type 1 - 8 [²²²] 1 - 8 [²²²]
P113 • Drive model 0 - 29 [²²²]0 - 29 [²²²]
P121 Enable/disable RUN button 0 - 1 [1] 0 - 1 [1]
P122 Enable/disable FORWARD/REVERSE
button
0 - 1 [1] 0 - 1 [1]
P123 Enable/disable JOG button 0 - 1 [1] 0 - 1 [1]
P124 Enable/disable ñ and ò buttons 0 - 1 [1] 0 - 1 [1]
P125 • Reverse direction inhibit 0 - 1 [1] 0 - 1 [1]
P128 • Fan switch-off delay time (seconds) 0-600 [120] 0-600 [120] MMV
P131 • Frequency setpoint (Hz) 0.00 - 400.00 [-] 0.00 - 650.00 [-]
P132 • Motor current (A) 0.0 - 99.9 [-] 0.0 - 300.0 [-]
P133 • Motor torque
(% nominal torque)
0 - 250 [-] 0 - 250 [-]
P134 • DC link voltage (V) 0 - 1000 [-] 0 - 1000 [-]
P135 • Motor RPM 0 - 9999 [-] 0 - 9999 [-]
P137 • Output voltage (V) 0 - 1000 [-] 0 - 1000 [-]
P138 Instantaneous rotor/shaft frequency
(Vector mode only)
- 0.00 - 650.00 [-]
P139 Peak output current detect 0.0-99.9 [-] -
P140 Most recent fault code 0 - 255 [-] 0 - 255 [-]
P141 Most recent fault code - 1 0 - 255 [-] 0 - 255 [-]
P142 Most recent fault code - 2 0 - 255 [-] 0 - 255 [-]
P143 Most recent fault code - 3 0 - 255 [-] 0 - 255 [-]
P186 • Motor instantaneous current limit (%) - 0 - 500 [200]
P201 • PID closed-loop mode 0 - 2 [0] 0 - 1 [0]
P202 • P gain 0.0 - 999.9 [1.0] 0.0 - 999.9 [1.0]
P203 • I gain 0.00 - 99.9 [0.00] 0.00 - 99.9 [0.00]
P204 • D gain - 0.0 - 999.9 [0.0]
P205 • Sample interval 1 - 2400 [1] 1 - 2400 [1]
P206 • Transducer filtering 0 - 255 [0] 0 - 255 [0]
P207 • Integral capture range (%) 0 - 100 [100] 0 - 100 [100]
P208 Transducer type 0 - 1 [0] 0 - 1 [0]
P210 Transducer reading (%) 0.00 - 100.00 [-] 0.00 - 100.00 [-]
P211 • 0 % setpoint 0.00 - 100.00 [0.00] 0.00 - 100.00 [0.00]