4-4
Ladder Logic (LAD) for S7-300 and S7-400
C79000-G7076-C504-02
4.2 Selecting a Method
When you create a DB in the SIMATIC Manager or in the LAD Editor, you
must select the method you want to use. You are prompted to select the
method in a dialog box.
New Data Block
Cancel
Create
R
eference:
OK Help
D
ata Block
Data Block Referencing a U
ser-Defined Data Type
Data Block Referencing a F
unction Block
Block: DB7
P
rogramming Tool: DB Editor
FB6
FB88
FB101
Figure 4-2 Selecting a Method and Assigning an FB/UDT
When creating a DB based on either a UDT or as an instance data block of an
FB, you make your selection in the list box that displays all existing UDTs
and FBs. The UDT or FB must already exist.
How you proceed from here depends on whether you are creating the DB by
assigning it or by creating a single declaration.
S Since the assigned UDT or FB defines the structure of the data block, you
have actually already created the new data block. The declaration table is
displayed on your screen, but no further changes can be made to it.
S If you are defining the structure of a shared data block, you must now edit
the declaration table, declaring the variable names and data type and, if
you require, the initial value and comment (see Section 4.3).
Procedure
How to Proceed
Creating Data Blocks and User-Defined Data Types
Kommentare zu diesen Handbüchern