Configuring with Web Based Management
5.5 "System" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
148 Configuration Manual, 11/2014, C79000-G8976-C323-03
The first table column shows the client type for which you are making the settings:
E-Mail
Sending system event messages by e-mail
Log Table
Entry of system events in the log table
Syslog
Entry of system events in the Syslog file
Select the required level from the drop-down lists of the second table column.
You can select from the following values:
Critical
System events are processed as of the severity level "Critical".
Warning
System events are processed as of the severity level "Warning".
Info
System events are processed as of the severity level "Info".
Procedure
Follow the steps below to configure the required level:
1. Select the required values from the drop-down lists of the second table column after the
client types.
2. Click the "Set Values" button.
5.5.9
SMTP Client
Network monitoring with e-mails
The device provides the option of automatically sending an e-mail if an alarm event occurs
(for example to the network administrator). The e-mail contains the identification of the
sending device, a description of the cause of the alarm in plain language, and a time stamp.
This allows centralized network monitoring to be set up for networks with few nodes based
on an e-mail system. When an e-mail error message is received, the WBM can be started by
the Internet browser using the identification of the sender to read out further diagnostics
information.
On this page, you can configure up to three SMTP servers and the corresponding e-mail
addresses.