Configuring with Web Based Management
5.5 "System" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
180 Configuration Manual, 11/2014, C79000-G8976-C323-03
Procedure
Enabling function
1. Select the "Syslog Client" check box.
2. Click the "Set Values" button.
Creating a new entry
1. In the "Server IP Address" input box, enter the IP address or the FQDN name of the
Syslog server on which the log entries will be saved.
2. Click the "Create" button. A new row is inserted in the table.
3. In the "Server Port" input box, enter the number of the UDP port of the server.
4. Click the "Set Values" button.
Note
The default setting of the server port is 514.
Changing the entry
1. Delete the entry.
2. Create a new entry.
Deleting an entry
1. Select the check box in the row to be deleted.
2. Click the "Delete" button. All selected entries are deleted and the display is refreshed.
5.5.15
Fault Monitoring
5.5.15.1
Power Supply
Settings for monitoring the power supply
Configure whether or not the power supply should be monitored by the messaging system.
Depending on the hardware variant there are one or two power connectors (Line 1 / Line 2)
and a PoE power supply. With a redundant power supply, configure the monitoring
separately for each individual feed-in line.
A fault is then signaled by the message system when there is no power on a monitored line
(Line 1, Line 2 or PoE) or when the applied voltage is too low.
Note
You will find the permitted operating voltage limits in the operating instructions of the device.