Configuring with Web Based Management
5.4 "Information" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
91
Description
The table has the following columns:
Port
Shows the available ports.
Error types
The other columns after the port number contain the absolute numbers of the incoming
frames according to their error type.
In the columns of the table, a distinction is made according to the following error types:
CRC
Packets whose content does not match the CRC checksum.
Undersize
Packets with a length less than 64 bytes.
Oversize
Packets discarded because they were too long.
Fragments
Packets with a length less than 64 bytes and a bad CRC checksum.
Jabbers
VLAN-tagged packets with an incorrect CRC checksum that were discarded because
they were too long.
Collisions
Detected collisions.
Description of the button
"Reset Counter" button
Click "Reset Counter" to reset all counters. The counters are also reset by a restart on the
device.