Seitenansicht 260
Configuring with Web Based Management
5.9 "Security" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
261
Description
The page contains the following box:
"Refresh interval [s]" input box
Enter the refresh interval for the ARP table.
The table has the following columns:
Radio
Specifies the WLAN interface to which the settings relate.
Port
Specifies the VAP interface to which the settings relate.
SSID
Specifies the SSID to which the settings relate.
Enable
When enabled, the access restriction is used. You configure which devices are
accessible to the clients in "Security > Inter AP Blocking > Allowed Adresses".
Block Gratuitous ARP Request
When enabled, gratuitous ARP packets are not forwarded.
Block Non-IP Frames
When enabled, there is no exchange of non-IP packets, for example layer 2 packets
between the client and the devices configured on the access point as permitted
communications partners.