Configuring with Web Based Management
5.4 "Information" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
95
Description
Table 1 has the following columns:
Radio
Shows the available WLAN interfaces.
WLAN mode
Shows the transmission standard. If DFS is activated, the transmission standard
"802.11h" is not shown additionally but only the configured transmission standard
"802.11a".
Configured Channel
Shows the configured channel. If "Auto" is displayed, the access point searches for a free
channel itself.
Alternative DFS Channel
If the DFS function is enabled, the configured alternative channel of the access point is
displayed.
If "Auto" is displayed, the access point searches for an alternative channel itself.
If the DFS function is activated and the access point browses for primary users for 60
seconds before starting communication with the selected channel, the text "scanning ..."
is displayed instead of the channel.
Operative Channel
Shows the channel of the access point via which the access point communicates.