Configuring with Web Based Management
5.9 "Security" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
249
4. Repeat the new password in the "Password Confirmation" input box.
5. Click the "Set Values" button.
Note
The factory settings for the passwords when the devices ship are as follows:
admin: admin
user: user
If you log on the first
time or log on after a "Restore Factory Defaults and Restart", you
will be prompted to change the password.
Note
Changing the password in Trial mode
Even if you change the password in Trial mode, this change is saved immediately.
5.9.2
WLAN
5.9.2.1
Basic
Safety levels
To make the network secure, authentication and encryption are used. On this page, you
specify the security settings.
Note
Transmission standard IEEE 802.11 n
The transmission standard IEEE 802.11 n with the setting "802.11n" or "802.11 n only"
supports only WPA2/ WPA2
-PSK with AES in the security settings.
iPCF or iPCF-MC mode activated
If iPCF or iPCF
-MC mode is enabled, only "Open System" with the encryption method AES
is supported in the security settings.