Configuring with Web Based Management
5.3 "Wizard" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
57
Cable Length [m]
Enter the length of the flexible antenna connecting cable in meters between the device
and the external antenna.
Additional Attenuation [dB]
Here, specify the additional attenuation caused, for example, by an additional splitter.
Note
If you use other WLAN interfaces, make sure that you have adequate channel spacing.
5.3.1.6
Radio Settings
Introduction
On this Basic Wizard page, you specify the configuration for the WLAN interfaces.
Description
This table contains the following columns:
Radio
Shows the available WLAN interfaces.
Enabled
Enable or disable the WLAN interface. The WLAN interfaces are disabled when the
device is supplied.
Radio Mode
Shows the mode of the WLAN interface.
Frequency Band
Specify the frequency band. In client mode, dual-frequency operation is also possible.
Note
Configuring WLAN interfaces of the W786-2IA RJ-45 for different frequency bands
If both WLAN interfaces are configured for the
same frequency band on this device, there
may be mutual influence or interference. This applies in particular when there is a high
data throughput.