Configuring with Web Based Management
5.5 "System" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
166 Configuration Manual, 11/2014, C79000-G8976-C323-03
●
Last Synchronization Mechanism
This box displays how the last time-of-day synchronization was performed.
– Not set
The system time was not set.
– Manual
Manual time setting
– SNTP
Automatic time-of-day synchronization with SNTP
– NTP
Automatic time-of-day synchronization with NTP
– SIMATIC
Automatic time-of-day synchronization using the SIMATIC time frame
●
Shows whether the daylight saving time changeover is active:
– active (+1 hour)
The time in "Current System Time" is daylight saving time.
– inactive (+0 hours)
The time in "Current System Time" is not daylight saving time.
1. Enable the "Time Manually" option.
2. Click in the "System Time" input box.
3. In the "System Time" input box, enter the date and time in the format "MM/DD/YYYY
HH:MM:SS".
4. Click the "Set Values" button.
The date and time are adopted and "Manual" is entered in the "Last Synchronization
Mechanism" box.
On this page, you can create new entries for the daylight saving time changeover.
The table provides an overview of the existing entries.