EMCO WINNC SINUMERIK 810/820 T ALARMS / MESSAGES
H 5
3006 Nxxxx Wrong block structure
Cause: too much M/H/T/D/S/G commands in one
block, G commands of the same group
twice programmed in block, circle with more
than 2 axes or polar coordinate centre
point with more than 2 axes, scale factor
programmed twice in a block, change of
plane / zero offset / tool change / mirror
while contour draft, no valid contour draft
with the programmed addresses
Remedy: correct program
3008 Nxxxx Subroutine error
Cause: subroutine counter invalid
subroutine end with M30
nesting depth override
Remedy: correct subroutine counter
program M17, max. 4 subroutines nested
3011 Nxxxx To many axes/axis twice
Cause: the position (axis) was already program-
med, too much axes with block with thread/
mirror
Remedy: correct program
3012 Nxxxx Block not in memory
Cause: program end without M30, jump target not
found
Remedy: correct program
3021 Nxxxx CRC contour error
Cause: The tool radius is too large in relation to the
smallest contour element, contour violation
with full circle, programmed arc radius
smaller than the tool radius
Remedy: correct program
3042 Wrong picture
Remedy: switch off / on the PC, reprot to EMCO if
repeatable
3049 Wrong simulation area
Cause: With graphik simulation no or an invalid
simulation area was put in
Remedy: put in/correct simulation area
3081 Nxxxx CRC not selected for approaching
Cause: With soft approaching / leaving a contour
G41 or G42 must be active
Remedy: correct program
4100 Nxxxx No D-number active
Cause: cycle alarm: no tooloffset active
Remedy: activate tool correction (D)
4101 Nxxxx Cutter radius = 0
Remedy: enter cutter radius
4102 Nxxxx Cutter radius too large
Remedy: correct cutter radius
4103 Nxxxx Tool to wide
Remedy: L93: use other tool
4120 Nxxxx Spindle rotat. dir. n. progr.
Remedy: L94: program spindle direction
4121 Nxxxx Spindle not in tol. range
4122 Nxxxx Calculated feed too large
Remedy: L841: reduce feed
4140 Nxxxx Fin. part diam. too small
Remedy: alter program
4180 Nxxxx Option not available !
Remedy: order option (L841, L94)
4200 Nxxxx Check definition of R
Remedy: correct R32
6000 - 7999 Machine alarms
see "Machine Alarms"
8004 ORDxx Failure main-drive unit
8005 - 8009 ORDxx Internal error AC
Remedy: report to EMCO if repeatable
8010 ORDxx Syncr. error main drive
Cause: synchronisation mark missing for main drive
Remedy: report to service technician, if repeatable
8011 - 8013 ORDxx Internal error AC
Remedy: report to EMCO, if repeatable
8014 ORDxx Decel.-time of axis too high
Remedy: report to service technician, if repeatable
8018 ORDxx Internal error AC
Remedy: report to EMCO, if repeatable
8021 ORDxx Internal error AC
Remedy: report to EMCO, if repeatable
8022 ORDxx Internal error AC
Remedy: report to EMCO, if repeatable
8023 ORDxx Invalid Z value for helix
Cause: The Z value of the helix must be smaller
than the length of the arc to be traversed
Remedy: Program correction
8100 Fatal init error AC
Cause: Internal error
Remedy: Restart software or reinstall when neces-
sary, report to EMCO, if repeatable.
8101 Fatal init error AC
see 8101.
8102 Fatal init error AC
see 8101.
8103 Fatal init error AC
see 8101.
Kommentare zu diesen Handbüchern