EMCO WINNC SINUMERIK 810/820 T ALARMS / MESSAGES
H 11
6013: MAIN DRIVE NOT READY
Main drive power supply defective or main drive too
hot, fuse defective, over- or undervoltage from mains.
A running program will be stopped, the auxilliary
drives will be switched off.
Check fuses or contact EMCO Service.
6014: NO MAIN SPINDLE SPEED
This alarm will be released, when the spindle speed
is lower than 20 rpm because of overload.
Alter cutting data (feed, infeed, spindle speed).
The CNC program will be aborted, the auxiliary
drives will be switched off.
6024: MACHINE DOOR OPEN
The door was opened while a machine movement.
The program will be aborted.
6040: TOOL TURRET INDEX FAILURE
The tool turret is in no locked position, tool turret
sensor board defective, cabling defective, fuse
defective.
A running CNC program will be stopped.
Swivel the tool turret with the tool turret key, check
fuses or contact EMCO service.
6041: TOOL CHANGE TIMEOUT
Tool drum stucks (collision?), fuse defective,
hardware defective.
A running CNC program will be stopped.
Check for collisions, check fuses or contact EMCO
service.
6043: TOOL CHANGE TIMEOUT
Tool drum stucks (collision?), fuse defective,
hardware defective.
A running CNC program will be stopped.
Check for collisions, check fuses or contact EMCO
service.
6046: TOOL TURRET ENCODER FAULT
Fuse defective, hardware defective.
Check fuses or contact EMCO service.
6048: CHUCK NOT READY
Attempt to start the spindle with open chuck or
without clamped workpiece.
Chuck stucks mechanically, insufficient pressured
air supply, fuse defective, hardware defective.
Check fuses or contact EMCO service.
6049: COLLET NOT READY
see 6048
PC TURN 120/125/155
The following alarms are valid for the
PC TURN 120/125/155.
6000: EMERGENCY OFF
The EMERGENCY OFF key was pressed.
The reference position will be lost, the auxiliary
drives will be switched off.
Remove the endangering situation and restart
machine and software.
6001: PLC-CYCLE TIME EXCEEDING
The auxiliary drives will be switched off.
Contact EMCO Service.
6002: PLC - NO PROGRAM CHARGED
The auxiliary drives will be switched off.
Contact EMCO Service.
6003: PLC - NO DATA UNIT
The auxiliary drives will be switched off.
Contact EMCO Service.
6004: PLC - RAM MEMORY FAILURE
The auxiliary drives will be switched off.
Contact EMCO Service.
6008: MISSING CAN SUBSCRIBER
Check fuses or contact EMCO Service.
6009: SAFETY CIRCUIT FAULT
Defective step motor system.
A running CNC program will be interrupted, the
auxiliary drives will be stopped, the reference position
will be lost.
Contact EMCO Service.
6010: DRIVE X-AXIS NOT READY
The step motor board is defective or too hot, a fuse
is defective, over- or undervoltage from mains.
A running program will be stopped, the auxiliary
drives will be switched off, the reference position will
be lost.
Check fuses or contact EMCO service.
6011: DRIVE Y-AXIS NOT READY
see 6010.
6012: DRIVE Z-AXIS NOT READY
see 6010.