8104 Fatal system error AC
see 8101.
8105 Fatal init error AC
see 8101.
8106 No PC-COM card found
Cause: PC-COM board can not be accessed (ev.
not mounted).
Remedy: Mount board, adjust other address with
jumper
8107 PC-COM card not working
see 8106.
8108 Fatal error on PC-COM card
see 8106.
8109 Fatal error on PC-COM card
see 8106.
8110 PC-COM init message missing
Cause: Internal error
Remedy: Restart software or reinstall when neces-
sary, report to EMCO, if repeatable.
8111 Wrong configuration of PC-COM
see 8110.
8113 Invalid data (pccom.hex)
see 8110.
8114 Programming error on PC-COM
see 8110.
8115 PC-COM packet acknowledge missing
see 8110.
8116 PC-COM startup error
see 8110.
8117 Fatal init data error (pccom.hex)
see 8110.
8118 Fatal init error AC
see 8110, ev. insufficient RAM memory
8119 PC interrupt no. not valid
Cause: The PC interrupt number can not be used.
Remedy: Find out free interrupt number in the Win-
dows95 system control (allowed: 5,7,10,
11, 12, 3, 4 und 5) and enter this number in
WinConfig.
8120 PC interrupt no. unmaskable
see 8119
8121 Invalid command to PC-COM
Cause: Internal error or defective cable
Remedy: Check cables (screw it); Restart software
or reinstall when necessary, report to
EMCO, if repeatable.
8122 Internal AC mailbox overrun
Cause: Internal error
Remedy: Restart software or reinstall when neces-
sary, report to EMCO, if repeatable.
8123 Open error on record file
Cause: Internal error
Remedy: Restart software or reinstall when neces-
sary, report to EMCO, if repeatable.
8124 Write error on record file
Cause: Internal error
Remedy: Restart software or reinstall when neces-
sary, report to EMCO, if repeatable.
8125 Invalid memory for record buffer
Cause: Insufficient RAM, record time exceeding.
Remedy: Restart software, ev. remove drivers etc. to
gain more RAM, reduce record time.
8126 AC Interpolation overrun
Cause: Ev. insufficient computer performance.
Remedy: Set a longer interrupt time in WinConfig.
This may result in poorer path accuracy.
8127 Insufficient memory
Cause: Insufficient RAM
Remedy: Close other programs, restart software,
ev. remove drivers etc. to gain more RAM.
8128 Invalid message to AC
Cause: Internal error
Remedy: Restart software or reinstall when neces-
sary, report to EMCO, if repeatable.
8129 Invalid MSD data - axisconfig.
see 8128.
8130 Internal init error AC
see 8128.
8130 Internal init error AC
see 8128.
8132 Axis accessed by multiple channels
see 8128.
8133 Insufficient NC block memory AC
see 8128.
8134 Too much center points programmed
see 8128.
8135 No centerpoint programmed
see 8128.
8136 Circle radius too small
see 8128.