EMCO WINNC SINUMERIK 810/820 T ALARMS / MESSAGES
H 9
9023 Control keyboard not connected
Remedy: Connect control keyboard, switch on ...
9024 General RS232 communication error
Remedy: Correct settings of the serial interface.
9500 Invalid memory for program
Cause: the PC has not enough free RAM
Remedy: Close all other WINDOWS applications,
eventually remove resident programs from
RAM, restart PC
9501 Error while saving program
Cause: disk full?
9502 Too less memory (loading prog.)
see 9500
9508 Selected menu not found
Remedy: report to EMCO, if repeatable
9509 Too less memory for picture
Remedy: report to EMCO, if repeatable
9510 Mem.-fail. block-search buffer
Remedy: report to EMCO, if repeatable
9511 Projection error block search
Remedy: report to EMCO, if repeatable
9540 Error in BFM / BFM not foand
Remedy: report to EMCO, if repeatable
Machine Alarms
These alarms are released by the machine.
The alarms are different for the PC TURN 50/55 and
the PC TURN 120/125/155.
The alarms 6000 - 6999 normally must be
acknowledged with RESET. The alarms 7000 - 7999
are messages which will disappear usually when the
alarm releasing situation is eliminated.
PC TURN 50/55
The following alarms are valid for the
PC TURN 50/55.
6000: EMERGENCY OFF
The EMERGENCY OFF key was pressed. Remove
the endangering situation and restart machine and
software.
6001: CYCLE TIME EXCEEDS LIMIT
Contact EMCO Service.
6002: NO PLC PROGRAM LOADED
Contact EMCO Service.
6003: DB NOT EXISTENT
Contact EMCO Service.
6004: RAM ERROR ON PLC BOARD
Contact EMCO Service.
6009: FAILURE SAFETY CIRCUIT
Defective door limit switch or main contactor. Opera-
ting the machine is not possible.
Contact EMCO Service.
6010: X-AXIS NOT READY
Step motor board defective or too hot, 24 V fuse
defective. Check fuses and switch box fan filter.
Contact EMCO Service.
6011: Y-AXIS NOT READY
see 6010.
6012: Z-AXIS NOT READY
see 6010.
6013: MAIN DRIVE NOT READY
Main drive power supply defective, cable defective,
fuse defective.
Check fuse.
Contact EMCO service.
6014: NO SPEED FOR MAIN SPINDLE
This alarm will be released, when the spindle speed
is lower than 20 rpm because of overload.
Alter cutting data (feed, infeed, spindle speed).
Kommentare zu diesen Handbüchern