EMCO WINNC SINUMERIK 810/820 T ALARMS / MESSAGES
H 9
9023 Control keyboard not connected
Remedy: Connect control keyboard, switch on ...
9024 General RS232 communication error
Remedy: Correct settings of the serial interface.
9500 Invalid memory for program
Cause: the PC has not enough free RAM
Remedy: Close all other WINDOWS applications,
eventually remove resident programs from
RAM, restart PC
9501 Error while saving program
Cause: disk full?
9502 Too less memory (loading prog.)
see 9500
9508 Selected menu not found
Remedy: report to EMCO, if repeatable
9509 Too less memory for picture
Remedy: report to EMCO, if repeatable
9510 Mem.-fail. block-search buffer
Remedy: report to EMCO, if repeatable
9511 Projection error block search
Remedy: report to EMCO, if repeatable
9540 Error in BFM / BFM not foand
Remedy: report to EMCO, if repeatable
Machine Alarms
These alarms are released by the machine.
The alarms are different for the PC TURN 50/55 and
the PC TURN 120/125/155.
The alarms 6000 - 6999 normally must be
acknowledged with RESET. The alarms 7000 - 7999
are messages which will disappear usually when the
alarm releasing situation is eliminated.
PC TURN 50/55
The following alarms are valid for the
PC TURN 50/55.
6000: EMERGENCY OFF
The EMERGENCY OFF key was pressed. Remove
the endangering situation and restart machine and
software.
6001: CYCLE TIME EXCEEDS LIMIT
Contact EMCO Service.
6002: NO PLC PROGRAM LOADED
Contact EMCO Service.
6003: DB NOT EXISTENT
Contact EMCO Service.
6004: RAM ERROR ON PLC BOARD
Contact EMCO Service.
6009: FAILURE SAFETY CIRCUIT
Defective door limit switch or main contactor. Opera-
ting the machine is not possible.
Contact EMCO Service.
6010: X-AXIS NOT READY
Step motor board defective or too hot, 24 V fuse
defective. Check fuses and switch box fan filter.
Contact EMCO Service.
6011: Y-AXIS NOT READY
see 6010.
6012: Z-AXIS NOT READY
see 6010.
6013: MAIN DRIVE NOT READY
Main drive power supply defective, cable defective,
fuse defective.
Check fuse.
Contact EMCO service.
6014: NO SPEED FOR MAIN SPINDLE
This alarm will be released, when the spindle speed
is lower than 20 rpm because of overload.
Alter cutting data (feed, infeed, spindle speed).