Siemens NRN 67 Series Spezifikationen Seite 63

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 87
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 62
RSSB Page 63 of 87
GSM-R user procedures (cab radio Version 2)
7.5.1.2 Signaller calls driver
GSM-R GB
1A26
Salisbury panel 1
Incoming call
7.5.1.3 Signaller clears signal
The signaller could clear the signal. In this case you will not receive any further
communication.
Press to clear the display of the ‘standing at signal’ message.
7.5.1.4 If the signaller does not respond
If you receive no response from the signaller, and the signaller has not cleared the signal
within a reasonable period, you must make a voice call to the signaller.
7.5.2 DSD alarm message
If you release the DSD with the master switch in Forward or Reverse, after 1 minute the
radio will send a DSD Alarm message to the signaller to let him/her know that you may
need assistance.
If at any time you are required to vacate the cab to perform other duties, ensure the
master switch is not left in the Forward or Reverse position to avoid sending spurious
DSD alarms to the signaller.
GSM-R GB
1A26
Press X to cancel
Preparing DSD Alarm
GSM-R GB
1A26
DSD Alarm
Sending
GSM-R GB
1A26
DSD Alarm
Sent
The signaller could make a point-to-point voice
call to you, to pass specific information, for
example, authority to pass the signal at danger.
30 seconds after the DSD has been released, the
radio will prepare to send the DSD alarm.
The cab radio will sound a continuous audible
alarm and display a message to this effect for a
further 30 seconds.
The DSD Alarm message will be sent to the
signaller at the end of this period unless the DSD
is reset or you press the cancel button on the
cab radio.
The cab radio confirms that the message has
been sent to the signaller.