INSTALLATION UM344-2
September 1995
3. At the Electronics Module, remove the meter mounting bracket attached to the left corner of
bottom circuit board . Install bracket in right front corner of that circuit board.
Hex Stand-Off
and
Digital Meter Assembly
Mounting Screw
Bracket and
Digital Meter Assembly
Mounting Screw
Note 2
90 and 270 Digital Meter
Mounting Hardware Location
o o
0 and 180 Digital Meter
Mounting Harware Locations
oo
Notes:
1. Enclosure Cap and Digital Meter removed to show Meter mounting hardware.
2. Bracket screwed to the Electonics Module.
3. Meter orientations relative to Transmitter body are shown.
4. Jumper W1, Zero and Full Scale Pushbutton Enable/Disable:
Enable - jumper pins 2 & 3
Disable - jumper pins 1 & 2.
5. When installing an Electronics Module, guide blocks must engage guide posts in
housing. P1 power connector on Module must engage connector on baseboard.
Electronics Module
Notes 1 and 5
X028AAS0
Meter Orientation
Note 3
Connector P2,
for Ribbon Cable
to Digital Meter
W1, Note 4
Electronics Module
Securing Screw
Guide Blocks
FIGURE 4-9 Digital Meter Orientation and Mounting Hardware
4. Rotate the Digital Meter assembly either CW or CCW 90° (to the 90° or 270° position), slip the
assembly under the retaining screws, and tighten both screws.
5. Position the cable in the cable slot and insert the cable connector into the closest connector (J2 or
J4).
6. Replace the enclosure cap and restore power to transmitter.
Kommentare zu diesen Handbüchern