Displayed only if a PE reintegration is in progress, this attribute displays the
progress in terms of percentage complete.
NOTE: Displayed for NonStop NS14000 series and NS16000 series
servers only.
PE (A/B/C) Reintegration Progress
Indicates the status of the PE reintegration process. Possible values include:
No current or pending operation
PE (A/B/C) Reintegration Status
Blade Element reset in progress
Blade Element reset complete
Reintegration setup in progress
Reintegration copy in progress
Reintegration copy complete
Reintegration final phase in progress
Reintegration complete
Complex invalid - no current or pending operations
Last operation failed
Operation scheduled
Settling period - no resets/reintegrations performed
Reset enabled
Reintegration enabled
Unknown
NOTE: Displayed for NonStop NS14000 series and NS16000 series
servers only.
The state of the PE.
Values: Running NSK, Halted State Services, Primitive, Primitive-Unable to
Join, Dead
PE (A/B/C) State
Displayed only if the PE State is something other than "Running NSK." This
attribute indicates why the PE is in its current state.
PE (A/B/C) Stop Code
The part number of the microprocessor assembly that was assigned in
manufacturing. Use part numbers for identifying and ordering parts.
NOTE: Displayed for NonStop NS14000 series and NS16000 series
servers only.
Replacement Part Number
LSU Logic Board
NOTE: These attributes are displayed for NonStop NS14000 series and NS16000 series servers
only.
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Hardware Revision
The version of the complex programmable logic device (CLPD) on the LSU
Logic Board.
LSU CPLD Version
The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.
Part Number
Status of the LSU power supply on Rail A.Rail A Power Status
Status of the LSU power supply on Rail B.Rail B Power Status
The serial number of the component assigned to it by the supplier of the
component.
Serial Number
The ID of the slot in which the LSU logic board resides.Slot ID