Siemens OSM Betriebsanweisung Seite 256

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 306
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 255
Midplane Physical
Whether the primary power source is On or Off.Primary AC Power State
Whether the backup power source is On or Off.Backup AC Power State
The part number of the switch module midplane.Part Number
Whether the switch module is installed and responding.
Values: Present, Absent, and Unknown
Presence
The track ID of the switch module midplane.Track ID
Identifies the manufacturer of the component.Manufacturer
The hardware revision of the switch module midplane.Hardware Revision
Logical
A unique, read-only number stored in nonvolatile memory (SEEPROM) on a
cluster switch. The Globally Unique ID can be used programmatically to
identify the switch.
Globally Unique ID
The current value of the 4-digit numeric selector setting.
Example: 9621
Current Numeric Selector Setting
User-assigned text, that can be used to help identify the module. The text is
assigned by using the Set Locator action.
Example: Switch Group On Right in 1206
Locator
The 4-digit numeric selector setting that is currently used by the firmware.
Example: 9621
Numeric Selector Setting Used by
Firmware
Temperature
The current temperature, in degrees Celsius (°C), inside the enclosure of the
module.
Current Value
The maximum acceptable air intake temperature is 65 degrees Celsius. If
the temperature rises above 65 degrees, an alarm is generated.
Normal Maximum Value
Actions
Blink All LEDs Off
Turns off the blinking of the fault LEDs on the switch logic board, PICs, power supplies and fans.
SCF Equivalent: ALTER SWITCH, BLINK NONE
Blink All LEDs On
Causes the fault LEDs on the switch logic board, PICs, power supplies, and fans to start blinking.
SCF Equivalent: ALTER SWITCH, BLINK ALL
Connect to UPS
Starts a new Internet Explorer window and loads the default HTTP home page provided by the
UPS vendor.
Parameter: IP Address (the IP address of the UPS)
Replace
Invokes the Replace Switch Component guided procedure that helps to replace the switch module.
256 Cluster Resources