Keypads
104
Building Technologies
Fire Safety & Security Products
Keypad Fire Outs
P85E 1-8E 1-8E
(includes
& or & )
A Keypad generated Fire Alarm (either pressing the
& or & together)
can be assigned to an output or multiple outputs. This can be used to operate an
audible or visual alarm connected to the output.
Option 1 = Output 1; Option 2 = Output 2 etc.
Keypad Medical Outs
P86E 1-8E 1-8E
(includes
& or & )
A Keypad generated Medical Alarm (either pressing the
& or &
together) can be assigned to an output or multiple outputs. This can be used to
operate an audible or visual alarm connected to the output.
Option 1 = Output 1; Option 2 = Output 2 etc.
Keypad Panic Beep
P90E 1-8E 1-8E
When a keypad generated Panic Alarm is generated, the alarm can be silent or it
can operate the buzzer in the keypad.
Option 1 = Output 1; Option 2 = Output 2 etc.
Keypad Fire Beep
P91E 1-8E 1-8E
When a keypad generated Fire Alarm is generated, the alarm can be silent or it
can operate the buzzer in the keypad.
Option 1 = Output 1; Option 2 = Output 2 etc.
Keypad Medical Beep
P92E 1-8E 1-8E
When a keypad generated Medical Alarm is generated, the alarm can be silent or it
can operate the buzzer in the keypad.
Option 1 = Keypad 1; Option 2 = Keypad 2 etc.
18.11 Keypad wrong code and manipulation alarms to outputs
Keypad Duress Outs
P87E 1-8E 1-8E
A Keypad generated Duress Alarm (see chapter
13.2: Duress digit; Duress Digit;
P25E 2E) can be assigned to an output or multiple outputs. This can be used to
operate an audible or visual alarm connected to the output. A Duress alarm is
created when the alarm is disarmed with the Duress digit preceding a valid User
Code.
Option 1 = Output 1; Option 2 = Output 2 etc.