Siemens IC60 Bedienungsanleitung Seite 23

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 172
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 22
System overview
23
Building Technologies
Fire Safety & Security Products
Example: Interface connection to open collector
23
OUTPUTS OUT 4
CNCN
_
+
C
Z1Z10V 12V C C CZ2 Z3 Z4
O
...
...
Battery Specifications for Sintony 60 compact
z Ni-MH Rechargeable Battery 12V/1.8Ah.
z Battery cutoff level (when AC mains fail): 10.5 ±0.1V.
z Full charge after 48 hours.
z The current limit over charge is 260 mA.
Battery Connections
Place the battery in its location, and secure it with the rubber band (refer to
Fig. 6).
Connect the battery plug into its connector (refer to
Fig. 3).
General Specifications:
z The range of the 12 V Out which is used for feeding sensors is between 10.2 to
14.3 V DC (working on mains or standby battery) .Ripple up to 0.1V p.p.
z Each voltage out 12 V protected by reset able fuse of 500 mA.
z The max total current allowed to draw during Alarm is 0.8 A.
z Self current consumption from battery is : 60 mA
z Operating temperature: 0-50º C
z Max. current consumption from the mains less than 150 mA.
z The panel is equipped with a type A power supply according EN 50131-6
z AC mains input 100 V AC – 240 V AC, 50/60 Hz
z The build in sounder has a value of > 100dB
z The main fuse AC = T250 mA, 250 V glass
To meet the EN 50131 and the T014 (Belgium) to withstand battery life not less of 12 hours please
note that the maximum current for accessories in standby mode should be less then 65 mA.