Miscellaneous panel and timing settings
75
Building Technologies
Fire Safety & Security Products
13 Miscellaneous panel and timing settings
13.1 Installer code
Installer Code
P25E 1E
This code is used to enter full Installer Program Mode. The default Installer Code is
258369. This code can only be changed while in Installer Program Mode. To enter
your new Installer Code press P25E 1E. The existing code will displayed at the
keypad on the bottom line of the LCD display. To change the code simply enter the
digits of the new code and it will replace the old one. The Installer Code must be
between 4-6 digits in length.
13.2 Duress digit
The system is only able to work with codes of a maximum length of 6 digits. If a duress code shall be
used within the system, the individual codes of the users are restricted to a maximum length of 5
digits.
Duress Digit
P25E 2E 0-9E
Value can be 1-9, 0 = Duress Disabled
The duress digit can be a number from 1-9 (a value of 0 means the duress function
is disabled).
To create a duress alarm the duress digit must be entered before a valid user code
(e.g. If the code is 12345 and the duress number is programmed as 4, then
entering a code of 412345 and press
would create a duress alarm).
13.3 Dial report delay
Reporting Delay
P25E 3E 0-255E
(0-255 Seconds)
If this address is set to 0, there will be no report delay. If it is set to any value other
than 0 then a delay equal to the programmed value will stop the panel from
reporting an alarm until this delay time expires.
Valid as of version 9.07: (both during the exit delay time if option 3 is on at P122E
for a zone or when an instant zone is triggered when fully armed). While the timer
is active certain outputs can be disabled at location P36E Option 5. Once the timer
has expired it will not start again, the panel must be disarmed then armed to reset
the timer.