Voice board IAV6-90
34
Building Technologies
Fire Safety & Security Products
6.2 Programming the voice messages
You can switch between two modes using the slide switch:
z Normal (default setting): internal speaker deactivated
z Test: internal speaker activated
When you leave the room, set the voice board to Normal mode.
6.2.1 Pre-configuration
There are two types of messages: Command control messages and alarm
messages. Command Control messages are used to give voice status information
when a user dials in to arm/disarm the system or to control outputs, zones and
additional events (using DTMF codes).
Alarm messages are assigned to alarm events and allow voice alarm.
Before programming the Command Control messages it is recommended to record
the messages and put them in a list.
For example:
Message No.
Order of recording
Voice Message
1 Output 4 on
2 Output 4 off
3 Output on
4 Output off
5 Area A armed
6 Area A disarmed
7 Area B armed
8 Area B disarmed
9 Zone 1 alarm
10 Zone 2 alarm
11 Zone 3 alarm
12 Mains failure
13 Mains restored
14 Battery low
15 Battery restored
…
37 Tamper