Configuring WLAN Services
Configuring a Basic WLAN Service
SCALANCE WLC711
User Guide, V8.11, 07/2012, C79000-G8976-C260-03 6-7
Table 6-2 Advanced WLAN Service Configuration Page
Field/Button Description
Timeout
Idle (pre) Specify the amount of time in minutes that a Mobile user can have
a session on the controller in pre-authenticated state during which
no active traffic is passed. The session will be terminated if no
active traffic is passed within this time. The default value is 5
minutes.
Idle (post) Specify the amount of time in minutes that a Mobile user can have
a session on the controller in authenticated state during which no
active traffic is passed. The session will be terminated if no active
traffic is passed within this time. The default value is 30 minutes.
Session Specify the maximum number of minutes of service to be provided
to the user before the termination of the session.
RF - select one or more of the following options:
Suppress SSID Select to prevent this SSID from appearing in the beacon
message sent by the Wireless AP. The wireless device user
seeking network access will not see this SSID as an available
choice, and will need to specify it.
Enable 11h support Select to enable 11h support. By default this option is disabled.
Siemens recommends that you enable this option.
Apply power reduction to 11h clients Select to enable the Wireless AP to use reduced power (as does
the 11h client). By default this option is disabled. Siemens
recommends that you enable this option.
This option is available only if you enable 11h support.
Process client IE requests Select to enable the Wireless AP to accept IE requests sent by
clients via Probe Request frames and responds by including the
requested IE’s in the corresponding Probe Response frames. By
default this option is disabled. Siemens recommends that you
enable this option.
Energy Save Mode Select to reduce the number of beacons the AP transmits on a
BSSID when no client is associated with the BSSID. This reduces
both the power consumption of the AP and the interference
created by the AP when no client is associated.
Egress Filtering Mode
Enforce explicitly defined “Out” rules Traffic is filtered as configured. For more information, see
Configuring Egress Filtering Mode” on page 7-17.
Apply “In” rules to “out” direction traffic The role of the source and destination addresses are reversed.
For more information, see “Configuring Egress Filtering Mode” on
page 7-17.
Client Behavior
Block MU to MU traffic Select the Block Mu to MU traffic checkbox if you want to
prevent two devices associated with this SSID and registered as
users of the controller, to be able to talk to each other. The
blocking is enforced at the L2 (device) classification level.
Seitenansicht 202