Working with a Mesh Network
Simple Mesh Configuration
SCALANCE WLC711
10-2 C79000-G8976-C260-03, 07/2012, User Guide, V8.11
Simple Mesh Configuration
In a typical Mesh configuration, the Wireless APs are connected to the distribution system via an
Ethernet network, which provides connectivity to the SCALANCE IWLAN Controller.
However, when a Wireless AP is installed in a remote location and can’t be wired to the
distribution system, an intermediate Wireless AP is connected to the distribution system via the
Ethernet link. This intermediate Wireless AP forwards and receives the user traffic from the
remote Wireless AP over a radio link.
The intermediate Wireless AP that is connected to the distribution system via the Ethernet
network is called Mesh portal, and the Wireless AP that is remotely located is called the Mesh AP.
The following figure illustrates the Simple Mesh configuration:
Figure 10-1 Simple Mesh Configuration
Wireless Repeater Configuration
In Wireless Repeater configuration, a Mesh AP is installed between the Mesh Portal and the
destination Mesh AP. The Mesh AP relays the user traffic between the Mesh Portal and the
destination Mesh AP. This increases the WLAN range.
Wireless Controller
Mesh Portal
Mesh AP
Client Devices