Working with a Mesh Network
Deploying the Mesh System
SCALANCE WLC711
User Guide, V8.11, 07/2012, C79000-G8976-C260-03 10-13
Figure 10-10 Mesh Deployment
Note:
With the single Mesh VNS, the tree structure for the Mesh deployment will be as depicted on the bottom right
of Figure 10-10. You can also implement the same deployment using four Mesh VNSs, each for a set of
Wireless APs in the four corners of the building. Each set of Wireless APs will form an isolated topology and
will operate using a separate SSID and a separate Pre-shared key. For more information, see “Mesh WLAN
Services” on page 10-4
To Configure the Mesh Wireless APs Through the SCALANCE IWLAN Controller:
Before configuring Mesh, be sure that the following conditions are met:
Energy Save is set to Off
Beacon Interval is set to 100 msec
AP names are 32 characters or less for statistics display purposes
ATPC and DCS are both disabled.
If possible, follow these guidelines for the backhaul radio to achieve a balance of stability,
throughput, and latency:
Use a 5.2 GHz band for backhaul
Select a non-DFS channel for the Mesh Portal
Use a 40 MHz Channel Width and Short guard interval
Disable Aggregate MSDUs
Enable Aggregate MPDUs
Enable ADDBA support