Siemens Sinumerik 810T Bedienerhandbuch Seite 18

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 62
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 17
11 Alarms 09.91
11.8 Axis-specific RESET alarms
11.8 Axis-specific RESET alarms
DAC limit reached
Cyclically
No direct effect. The error enters the following error Alarm 156*
Setpoint at DAC is higher than input in MD 268* (max. DAC setpoint).
No further increase in setpoint possible!
Operate at lower speed
Check actual values (pulse generator)
Check MD 268*
Check drive actuator (tachogenerator compensation at Vmax.)
Check MD 364* and MD 368* (var. increment weighting)
Scan:
Effect:
Explanation:
Remedy:
104
*
Scan:
Effect:
Explanation:
Remedy:
108
*
Actual value difference overflow
With each axis movement (including in follow-up mode)
NC START disabled
Setpoint 0
NC Ready 2 cancelled
Servo enable cancelled after time in MD 156 has expired
Follow-up mode
Actual machine value is lost (wrong position)
With high-speed axis travel the register has overflown in the event
of an error. The reference point was lost in the process.
Reduce maximum speed. (Depending on MD 364* and 368*)
Check MD for variable increment weighting (MD 364* and
MD 368*).
11–18 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02