11 Alarms 09.91
11.8 Axis-specific RESET alarms
11.8 Axis-specific RESET alarms
DAC limit reached
Cyclically
No direct effect. The error enters the following error Alarm 156*
Setpoint at DAC is higher than input in MD 268* (max. DAC setpoint).
No further increase in setpoint possible!
• Operate at lower speed
• Check actual values (pulse generator)
• Check MD 268*
• Check drive actuator (tachogenerator compensation at Vmax.)
• Check MD 364* and MD 368* (var. increment weighting)
Scan:
Effect:
Explanation:
Remedy:
104
*
Scan:
Effect:
Explanation:
Remedy:
108
*
Actual value difference overflow
With each axis movement (including in follow-up mode)
• NC START disabled
• Setpoint 0
• NC Ready 2 cancelled
• Servo enable cancelled after time in MD 156 has expired
• Follow-up mode
• Actual machine value is lost (wrong position)
• With high-speed axis travel the register has overflown in the event
of an error. The reference point was lost in the process.
• Reduce maximum speed. (Depending on MD 364* and 368*)
• Check MD for variable increment weighting (MD 364* and
MD 368*).
11–18 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02