11 Alarms 09.91
11.11 Alarm list ACKNOWLEDGE
Explanation:
Remedy:
3007
Wrong setting data program
• G25 / G26 programmed
• G92 programmed with an address other than ”S” or ”P”
• M19 programmed with an address other than ”S”
As for Alarm 3000
Explanation:
Remedy:
• M30 programmed as program end
• M17 missing at program end
• 5th nesting depth activated
(only 4 subroutine levels possible with SINUMERIK 810)
• M17 programmed in main program
As for Alarm 3000
3008
Subroutine error
Explanation:
3009
Program disabled
L0 preselected in AUTOMATIC display (is prohibited)
Significance:
Remedy:
3010
Intersection error
This error may occur in conjunction with stock removal cycle L95
if:
• Contour program programmed without G0, G1, G2, G3
• @ 714 programmed in contour program
• Incorrect plane in contour program
• No intersection found
• More than quarter circle programmed in contour program
• No geometry in first block of contour program of L95
stock removal cycle
As for Alarm 3000
11–40 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02
SINUMERIK 810 GA3/820 GA3 (IA)