11 Alarms 11.90
11.11 Alarm list ACKNOWLEDGE
Explanation:
Remedy:
A variable has been selected which cannot be represented in control.
Check display using programming workstation; re-input variable if
necessary
3046
Variable error
Explanation:
Remedy:
3048
Wrong workpiece definition
Minimum and maximum values have been reversed when defining the
workpiece.
Example: Xmin. = 100
Xmax. = 50
Check workpiece definition for valid values.
Explanation:
Remedy:
No values or incorrect values have been input when defining the
simulation area.
Check values for simulation area (all levels).
Simulation may only be restarted after depressing
RESET and the ACKNOWLEDGE ALARM key.
3049
Wrong simulation area
Explanation: Simulation data incorrect/not defined.
3050
Incorrect input
Explanation:
Remedy:
3063
Data block not available
In PLC STATUS a DB No. was selected, which is not available.
Select or create correct DB.