09.91 11 Alarms
11.6 Alarm list POWER ON
Scan:
Effect:
Explanation:
9
Memory too small for UMS
With POWER ON
UMS declared invalid
On switching on, the contents of the UMS are checked and an address
list then prepared. This address list requires a certain amount of storage
space in the RAM area. UMS lists are too large.
Scan:
Effect:
Explanation:
Remedy:
10
UMS error
With POWER ON
UMS declared invalid
• MD 5015 bit 6 = 1 but no UMS inserted
• UMS (RAM) not loaded, i.e. empty
• Insert UMS
• Load UMS (RAM)
Scan:
Effect:
Remedy:
12
PP memory wrongly formatted
With POWER ON
• Error in RAM area of CPU or memory module
• The minimum size of the part program was
not reached
• module withdrawn
• Check MD 12 and depress ”CLEAR PARTPR.”
softkey.
Scan:
Effect:
Explanation:
Remedy:
11
Wrong UMS identifier
With POWER ON
UMS declared invalid
• UMS (RAM) not loaded, i.e. empty
• Contents of UMS not defined
a) UMS (RAM) overturned
b) UMS (EPROM) empty
• Wrong UMS inserted
• Error when linking with WS 800
• Insert correct UMS
• Reload UMS (RAM)
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02 11–9