11 Alarms 11.90
11.11 Alarm list ACKNOWLEDGE
Scan:
Effect:
Explanation:
Remedy:
3017
Part program no. occurs twice
With ”POWER ON RESET” (switching on of control)
NC START disabled
The EPROM card for the cycles has a part program
in duplicate
Check UMS
Scan:
Effect:
Explanation:
Remedy:
3018
Distance from contour too great
After NC start (automatic)
• Stop in processing
The distance from the circle contour (MD 9) is too large after
repositioning
Note MD 9, move closer to the contour
Explanation:
Remedy:
3019
Option RS 232 not available
The second RS 232 C (V.24) interface has been activated by the PLC
or using the soft key without the option being available.
• Transmit data via the first RS 232C interface
• Retrofit option C62 (second RS 232C interface)
A function has been programmed which is not available in the control.
• As for Alarm 3000
• Retrofit option
Explanation:
Remedy:
3020
Option not available
3021
Scan:
Explanation:
CRC/TNRC contour error
• With CRC/TNRC selected
NOT:
• in selection block
• in cancellation block
Correction calculation produces a traversing movement opposing the
programmed movement.
11–42 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02
SINUMERIK 810 GA3/820 GA3 (IA)