09.91 11 Alarms
11.9 General RESET alarms
Effect:
Remedy:
2048
Circle end point error
NC START disabled
Programmed circle end point not on circle
End point is further away by more than the input limit
in MD
No geometry in first block of contour subroutine with L95 stock
removal cycle
Correct program
Explanation:
Remedy:
2056
Travel thru transf. center
Radius axis (linear axis) tends to travel to the zero point of fictitious
coordinate system on the programmed path
Change cutter radius
Program different path motion
Significance:
Remedy:
2057
Opt. thread/rev. not available
A thread has been programmed with G33, G34, G35 although this
function is not implemented in the control
Feedrate per revolution G95 has been programmed
Correct program
Check MD
Explanation:
Remedy:
2058
3D option not available
3 axes programmed simultaneously
Programmed block results in movement of 3 axes
Correct program, check MD
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02 11–27