01.93 11 Alarms
11.6 Alarm list POWER ON
11.6 Alarm list POWER ON
Cause:
Scan:
Explanation:
Remedy:
Note:
1
Battery alarm - power supply
Voltage of back-up battery
• With POWER ON
• Cyclically
Replace battery (see Instruction Manual)
The battery voltage has dropped to such a level that buffering of the
user memories is only guaranteed for a short period.
Replace battery (see Instruction Manual).
Acknowledge alarm with
(from power supply unit version 6EV3055-0BC revision ”F”)
Do not switch control off, otherwise data may be lost !
Dispose of all batteries as special waste.
Cause:
Scan:
Effects:
Explanation:
Remedy:
3
PLC stop
PLC not ready
Cyclically
NC START disabled
• Setpoint 0 output
• NC Ready 2 (NCBB2) cancelled
• Servo enable cancelled after time in MD 156 has expired
• NC/PLC interface rendered inactive
• Resetting of all PLC outputs on I/O board
Cyclical and interrupt-driven operation of the PLC is interrupted.
Travel with the machine is not possible.
Using the PG (programmer) read out the cause of
interrupt (ISTACK). Evaluate PLC alarm on NC screen.
Scan:
Effect:
Explanation:
Remedy:
4
Incorrect unit system
• With POWER ON
• After modifying MD
• Conversion factor assumed to be 1
• An illegal combination has been selected (conversion factor greater
than ten) for the units of the measuring system (position control
resolution) and the unit of the input system.
• Position control resolution for rotary axis < 0.5 · 10
-3
degrees and
the ordering data option for this is missing.
Correct the MD bits then switch the control off and on or include the
ordering data option ”Position control resolution for rotary axis < 10
-3
degrees”
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02 11–7
SINUMERIK 810 GA3/820 GA3 (IA)