11 Alarms 09.91
11.9 General RESET alarms
Scan:
Explanation:
Effect:
Remedy:
2042
Parity error in memory
• During processing in automatic mode
One or more characters are deleted in the memory, so they
can longer be recognized (these characters are output
as ”?”)
NC START disabled
• Correct program in EDITOR or, if necessary, delete complete
block and re-input
• With a large number of ”?” the complete memory may
have been erased; in this case check the battery and reformat
the part program memory
Explanatio:n
2043
Progr. error on transform.
• Programming of real axes of the transformation group when
transformation has been selected.
• Programming of fictitious axes when transformation has been
deselected.
• Programming traversing movements in the selection block
Scan
Effect:
Explanation:
Remedy:
2046
Block > 120 characters
• During processing in automatic mode
• NC START disabled
”LF” is inverted in the memory producing a block of more
than 120 characters.
Insert ”LF” or delete complete block
Effect:
Explanation:
Remedy:
2047
Option not available
• NC START disabled
The programmed function is not included in the control's
function set.
Correct program, check MD
11–26 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02
SINUMERIK 810 GA3/820 GA3 (IA)
Kommentare zu diesen Handbüchern