Siemens Sinumerik 810T Bedienerhandbuch Seite 22

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 62
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 21
11 Alarms 01.93
11.8 Axis-specific RESET alarms
Scan:
Effect:
Explanation:
Remedy:
184
*
Stop behind reference point
During approach to reference point
NC START disabled
Setpoint 0
Reference point not reached
During approach to the reference point the axis was stopped between
the reference cam and zero mark of the measuring system.
Repeat approach to reference point
Cause:
Effect:
Remedy:
180
*
Axis in several channels
During simultaneous processing of two programs in different channels,
one axis has been programmed in both programs
(channels) such that a traversing movement for the axis in question
is output by both programs.
NC START disabled
Setpoint 0
Check both programs
172
*
+ Working area limit
During processing in automatic mode
During axis traversing in JOG, INC and REPOS mode
NC START disabled
Setpoint 0
Working area limitation in the setting data has been reached.
Check working limitation in setting data (select using ”Setting
Data”and ”Common Axial” soft keys)
Check program
Working area limitation in JOG mode only active when
NC MD 5003 bit 6 is set
176
*
- Working area limit
Scan:
Effect:
Explanation:
Remedy:
Note:
Explanation:
196
*
Follow-up/park for axis
The interface signal PARK for the axis is active
Changeover from spindle mode to rotary axis mode has not yet
taken place
11–22 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02
SINUMERIK 810 GA3/820 GA3 (IA)
Seitenansicht 21