Siemens Sinumerik 810T Bedienerhandbuch Seite 30

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 62
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 29
11 Alarms 11.90
11.9 General RESET alarms
Scan:
Effect:
Explanation:
Remedy:
2068
Pos. behind working area
During processing in AUTOMATIC/MDI
NC START disabled
Programmed travel not processed
Programmed end position of block is behind working area limitation in
one or more axes.
Check working area limitation (positive and negative)
Modify working area limitation by means of G25/G26
in program
Explanation:
2072
Incorrect input value (contour definition)
Value input not calculable for contour definition calculation.
Explanation:
2073
No intersection point (contour definition)
No intersection is obtained with programmed values when calculating
contour definition.
Explanation:
2074
Incorrect angle value (contour definition)
Angle 360° programmed
Angle value not practical for defined contour
Explanation:
2075
Incorrect radius value (contour definition)
Radius too large
Radius not permitted with defined contour
11–30 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02