11.90 11 Alarms
11.11 Alarm list ACKNOWLEDGE
Explanation:
Remedy:
3024
Display description not available
A configured softkey has been used to skip to a display which is not
available in the user memory submodule or system memory.
• Check display number
• Check softkey function
Explanation:
Remedy:
3025
Display description error
• A display with graphics has been configured but the control
does not have the ”Graphics” option.
• The selected display has too many variables or fields.
• A display type not known to the control has been configured.
• Check display with programming workstation
• Retrofit ”Graphics” option if necessary
Explanation:
Remedy:
3026
Graphics / text too volum.
• Configuring error in selected display
• Sum of graphics and text elements too large
• Check display with programming workstation
• Split contents over 2 displays if necessary
3027
Explanation:
Note:
Remedy:
Graphics command too volum.
Sum of graphics commands in selected display too large.
This alarm activates Alarm 3026.
• As for Alarm 3026
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02 11–43