09.91 11 Alarms
11.9 General RESET alarms
2037
Explanation:
Prog. S value too high
Programmed, overstored spindle speed ”S” exceeds ”16 000”.
Enter slower spindle speed (S value limited in control
to ”16 000”).
Explanation:
Effect:
Remedy:
2038
Path feed too great
• The value entered in the machine data ”Max. velocity” exceeds the
permitted value range.
• The programmed path of velocity results in an axial velocity which
is outside of the value range.
The axis number is displayed after N.
Blocking of NC Start and dropping out of setpoint relay.
Check the MD ”Max. velocity”. Observe the value range.
Scan:
Effect:
Significance:
Remedy:
2039
Reference point not reached
• In AUTOMATIC/MDI mode after NC START
• NC START disabled
The reference point was not approached in all
defined axes
• Approach reference point in axes concerned.
• Set NC MD 5004 bit 3 (NC START without reference point).
Caution: No software limit switches active.
• Set NC MD 560* bit 4.
Approach to reference point can then be suppressed for one or
more special axes on an axis-specific basis.
Caution: No software limit switches active in these axes.
Effect:
Explanation:
2040
Block not in memory
• NC START disabled
• The block number sought in block search is not available in
the program.
• With a jump in the program, the programmed block
number could not be found in the specified
direction.
Effect:
Explanation:
Remedy:
2041
Program not in memory
• NC START disabled
• Preselected program is not available in memory
• Subroutine called in program is not available
in memory
• Preselect correct program, check program overview
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02 11–25