4-9
SIMATIC 545/555/575 System Manual
Installing 575 System Hardware
The fan assembly is fused to protect the hardware from over-voltage or
other adverse power conditions. If you need to replace the fuse, use a 3 A, 3
AG, 1
1
@
4
-in. x
1
@
4
-in., 250 V, slow-blow fuse (PPX:2587679–8002). The fuse
holder is located on the front panel of the fan assembly. To replace a fuse,
follow these steps.
!
CAUTION
To minimize risk of shock hazard, always turn off all power from the fan
assembly before changing the fuse.
Failure to do so could cause death or serious injury and/or damage to
equipment.
Ensure that power to the base is turned off before changing the fuse.
1. Disconnect power to the fan assembly.
2. Insert a flat-bladed screwdriver in the fuse-holder slot and rotate
counterclockwise (about
1
@
8
turn) until it pops out (see Figure 4-3).
3. Remove the fuse, and insert a new fuse in the fuse holder.
4. Insert the fuse holder into the slot, push firmly against the spring, and
rotate clockwise until it locks in place.
5. Reconnect power to the fan assembly.
Fuse holder
Front Panel of
Fan Assembly
Turn counterclockwise
to remove.
Figure 4-3 Replacing Fuse on Optional Fan Assembly
Replacing Fuse on
the Fan Assembly
Kommentare zu diesen Handbüchern