4-12
Installing 575 System Hardware SIMATIC 545/555/575 System Manual
Installing the PPX:575–2130 VMEbus Base (continued)
Figure 4-7 shows the measurements required for rear mounting in a NEMA
cabinet or mounting against a wall. Rear mounting brackets are included
for these mounting options. The cabinet must provide a minimum depth of
12 inches to accommodate cabling from the front of installed modules. Leave
clearance of at least 3 inches above and below the base for proper cooling.
19.0 (483)
18.31 (465)
0.272
(6.9)
8 holes
0.35
(8.9)
12.25
(311)
diameter Measurements: in. (mm)
3.50 (89)
3.50 (89)
2.25 (57)
1.50 (38)
Figure 4-7 VMEbus Base Wall or Cabinet Mounting Measurements
Use the following steps for panel mounting in an NEMA cabinet.
1. Open NEMA enclosure door.
2. Drill four holes in sub-panel of NEMA enclosure with a #21 drill bit.
Refer to Figure 4-7 for screw-hole dimensions for each base.
Ensure that chips from drilling do not contaminate other equipment.
3. Position the base inside the NEMA enclosure.
NOTE: Be sure that the bracket holes and the tapped holes in the sub-panel
are aligned.
NEMA Cabinet
Mounting
Measurements
Panel Mounting the
Base