T400 Controller Facilities Manual
667/EB/20200/000 Page 12-5 Issue 9
12.3.1 Event Switch Default States
Event Default State
MaxSwitch Set A and Priority Plan 0 selected.
CondSwitch Conditioning flag false
I/P active Input normal operation (following external influence)
I/P inactive Input normal operation (following external influence)
O/P active Output normal operation (following controller influence)
O/P inactive Output normal operation (following controller influence)
Delete Stage Stage not deleted
Part Time Not Part time (i.e. signals illuminated normally)
Sign OFF Sign will be ON
Sign ON Sign will be OFF
Delete Phase Phase not deleted
Change Timeset Timeset A
12.4 PARAMETERS
All the required combinations of the event timetable facilities are programmed in a
parameter array. 16 parameters can be defined, each containing any of the 16 switches
(allocated to facilities, see Section 12.3). The switches are set to active for a parameter
by insertion of a ‘1’. This allows a timetable setting not only to switch facilities in and
out but also to maintain facilities at their current state (see Figure 21.13). The
parameter is then allocated to a timetable setting which consists of day type, hour,
minute and second (see Figure 21.12).
Any combinations not required initially, may be included in the parameter array for use
at a later date. The request for a parameter may be added to a timetable setting via the
handset using the TSW command. The parameter array cannot be changed by using the
handset.
The individual facilities may be introduced via the handset by using the SWS
command.
For example, refer to the intersection in section 21 and Figure 21.12 and Figure 21.13:
At 07:30 Alternative maximum Set B is introduced, Detector C1 is switched
inactive, Dummy Phase I is deleted and the secret sign (NRT) is
illuminated - Parameter 1. The last two facilities have the effect of
Stage 2 not appearing and preventing right turning traffic on Phase B.
At 09-00 Alternative Maximum Set B is replaced by Alternative Maximum Set C
but Detector C1 remains inactive, Dummy Phase I remains deleted and
the secret sign remains illuminated - Parameter 2.
At 10-00 The standard maximum Set A is restored, Detector C1 is allowed to
operate normally, Dummy Phase I remains deleted and the secret sign is
extinguished - Parameter 0.