T400 Controller Facilities Manual
667/EB/20200/000 Page 3-9 Issue 9
(i) Fixed Period during Manual Step-On. (Export only).
The timing range is 0 to 255 seconds in 1 second steps.
3.5.8 Limit Green Watchdog (Facility constructed in Special Conditioning for Export
Only).
In all modes except Hurry Call, Vehicle Actuated and Manual Control, the maximum
duration of each stage green can be governed by a limit green watchdog time. One
limit green watchdog timer (a Special Conditioning timer) is provided, which is applied
to each stage in turn.
The stage limit green watchdog timer commences timing when the stage green is
reached and is reset on a plan change, a mode change and when the stage terminates.
If the limit green override code is sent from the ATC computer during computer stage
control mode, the limit green watchdog timer is held reset.
In the event of a limit green watchdog timer timing out before its associated phase
green has terminated, the controller will then revert to the next highest priority mode
configured for which a request exists and the fault will be logged. If the current mode
at the time of failure is fixed time mode, the controller switches off the power to the
lamps.
3.6 HANDSET RANGE LIMITS AND THRESHOLD VALUES
The following handset commands have configurable minimum and maximum range
limits on the value of data which can be entered via the handset. There is only one
minimum limit and one maximum limit for each of the commands (with the exception
of minimum greens and intergreens which are described separately).
Minimum Green MIN
Green Extensions EXT
Maximum Green MAX
Phase Intergreen IGN
Phase Delays DPG
Pedestrian Flash Time PBT
Starting Intergreen Period SIG
Hurry Call Delay DHC
Hurry Call Hold HHC
Hurry Call Prevent PHC
Group Time PLT
Offset Time OFF
DFM Time DFD
Priority First Delay Timer PFD
Priority Second Delay Timer PSD