T400 Controller Facilities Manual
667/EB/20200/000 Page 18-14 Issue 9
Figure 18.8 - CONNECTING DUAL LEVEL AUDIBLES
Contact protection
resistor
(normally 22
)
SUPPLY
Change-over
contacts located on
expansion I/O board
Audio unit in wait
indicator
667/1/01478/006
Notes:-
(i) On an intersection controller, the supply for the audibles would
originate from a transformer mounted in the controller as shown in
Figure 18.2.
(ii) For a pelican controller, the supply will come from the 2-phase driver
board.
(iii) Note that the high current outputs are used, i.e. the contacts are
protected by a series resistor of 22.