T400 Controller Facilities Manual
667/EB/20200/000 Page 14-4 Issue 9
14.4 EXPORT SIGNAL SEQUENCES
The following is a list of some of the foreign signal sequences available. If other
sequences are required, consult with the Siemens Traffic Engineering Department.
BAHRAIN: Blackout start-up and flashing amber part-time with standard
British traffic and pedestrian sequences (no blackout).
Supply: 240V 50Hz.
CHINA:
Beijing: Normal startup sequence and blackout part-time mode.
Traffic: red - green - amber - red.
Supply: 220V 50Hz.
Shekou: Normal startup sequence and blackout part-time mode.
Traffic: as Beijing.
Ped: red man - green man - flashing green man - red man.
Supply: 220V 50Hz.
Shen Zhen Province: As Columbia, but 220V 50Hz.
COLUMBIA: Flashing amber start-up and part-time.
Traffic: red - green - amber - red.
Ped: red man - green man - flashing green man - red man.
Supply: 110V 60Hz.
DALLAH: Flashing amber start-up and part-time.
Traffic: red - green - amber - red.
Ped: red man - green man - blackout - red man
(usually as parallel peds).
Supply: 220V 60Hz
(except Dammam Port - 277V 60Hz. A special transformer is
needed here).
Side road flash in part time may be red instead of amber.
Amber leaving may also be requested as five seconds instead
of the normal three.
EIRE: Normal start-up.
Traffic: red - green - amber - red.
Ped: standard (sometimes with blackout).
Supply: 240V 50Hz.